3. With Synch connected between the ActivBoard and the computer,
press the * button quickly on the remote 5 times. The on-screen
message "CALIBRATION MODE" will appear. Pressing the *
button 5 times again will cancel the calibration routine.
4. Launch the calibration utility by from the ORANGE ICON in the
task bar (WIN) or the menu bar (MAC).
The calibration program will prompt you to click on the active area
with the pen to begin calibration.
5. Click the pen accurately on the center of each of the successive
cross-hairs. When you have clicked on five calibration crosses, the
calibration utility will automatically close.
The ActivBoard is now calibrated with Synch.

DIRECT MODE CALIBRATION

The Synch must operate in "DIRECT MODE" when using a
Promethean ActivBoard or SMART Board where the appropriate
software IS NOT installed on the local computer. This procedure
enables the interactive whiteboard to behave as a mouse input device
for computer control only.
To switch from SMART MODE to DIRECT MODE use the TANDBERG
Remote Control to press "#*#*#" (pound-star-pound-star-pound) to
initiate DIRECT MODE. Another option to put Synch in to DIRECT
MODE is to use a thin object (paper clip) and depress the button found
on the front of the Synch box until the DIRECT MODE message is
seen.
Press "#*#*#" to toggle between WHITEBOARD and DIRECT modes.
An ON-SCREEN MESSAGE will flash to indicate which mode the
system is in.
Whenever the Synch module is power-cycled it will revert to the default
WHITEBOARD MODE requiring recalibration in Direct Mode.
1. Set the projector image to fill the whiteboard area with no overlap
on the frame. It is acceptable if the image is slightly smaller than
the frame.
2. Set the codec image layout to full screen and select PC SOURCE
using the TANDBERG Remote.
3. With Synch connected between the interactive whiteboard and the
computer, press the * button quickly on the remote 5 times. The
on-screen message "CALIBRATION MODE" will appear.
Pressing the * button 5 times again will cancel the calibration
routine.
4. Touch the tip of the mouse cursor on the image displayed on the
interactive whiteboard. There are 3 locations to calibrate: top-left,
lower right & upper-right. After the upper right calibration has been
touched the calibration is complete.