Adjusting Orbital Dispenser Motor Speed - Graco PRECISIONSWIRL 310554V Instructions-Parts List Manual

Orbital dispenser
Table of Contents

Advertisement

PrecisionSwirl Module Operation

Adjusting Orbital Dispenser Motor Speed

Adjust the orbital dispenser motor speed in the manual or automatic control mode as described in the following para-
graphs.
Manual Mode:
Adjust motor speed by rotating the MANUAL SPEED
CONTROL knob on the control box. See F
Rotate the knob clockwise to increase speed and coun-
terclockwise to decrease speed. Use the motor speed
chart (F
. 13) to find the manual control setting required
IG
to achieve the desired motor speed.
0-10 VOLT
24
22
20
18
16
14
12
10
8
6
4
2
0
F
. 13
IG
24
. 12.
IG
PrecisionSwirl Motor Speed Command
0
1
2
3
Analog speed signal from robot (Volts dc)
Manual control setting
Automatic Mode:
Use the motor speed chart (F
setting required to achieve the desired motor speed.
When the control signal voltage is increased, the motor
speed increases. When the control signal voltage is
decreased, the motor speed decreases.
Exceeding the maximum analog speed control volt-
age may result in damage to the motor controller.
4
5
6
7
OR
. 13) to find the voltage
IG
8
9
310554V

Advertisement

Table of Contents
loading

Table of Contents