Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output (per
power supply)
System Inlet
Temperature
Relative Humidity
(non-condensing)
DA - 13669 Worldwide — Version 46 — December 13, 2013
6.94" x 19.0" x 27.55" (17.6cm x 48.3cm x 70.0cm)
Maximum
(all hard drives, power
supplies, DIMMs and
processors installed)
Minimum
(one hard drive, two power
supplies, four DIMMs, and
two processors installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
NOTE: To review typical system power ratings use the HP Power Advisor
which is available online located at url:
efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL580 G7
- Follow the instructions of the next screens.
Rated Steady-State Power 910 W (low line),
Maximum Peak Power
Operating
Non-operating
Operating
Non-operating
HP ProLiant DL580 Generation 7 (G7)
100.0 lb (45.4 kg)
66.0 lb (30.0 kg)
100 - 127 VAC,
200 - 240 VAC
12 A (at 100 VAC),
8 A (at 200 VAC)
50 to 60 Hz
1161 W (at 100 VAC),
1598 W (at 240 VAC)
3960 BTU/hr (at 100 VAC),
5450 BTU/hr (at 200 VAC)
www.hp.com/go/proliant-energy-
1300 W (high line)
910 W (low line),
1300 W (high line)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be limited
by the type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.