Condensed Water; Electrical Installation - Electrolux TW SL3 M100 Operating Instruction

Electrolux tumble dryer
Table of Contents

Advertisement

Installation

Condensed water

The machine is supplied as shown in Option 1
(inset). This means that the condensed water is
pumped into the condensed water container,
which must be removed and emptied by hand.
Option 2 allows you to remove the small short
hose from the nipple. Attach the rubber hose
supplied to the same nipple. The water can then
be pumped out into a sink or a floor drain (2a).
2
Max 1000 mm
1
2a

Electrical installation

If the machine is delivered from the factory with
a plug attached it can be connected to an earthed
wall socket. Otherwise, a permanent connection
using a multipolar circuit breaker must be made
by a qualified professional.
Connection on delivery
• 230V, 1-Phase, 10A
• 50Hz
• Use a type A residual-current device.
Coin operation
The machine is prepared for coin operation. Such
installation must be carried out by a qualified
professional.
The installation requires a connection cable to
power the coin meter. This connection cable can
be ordered using the factory art. no. 92 090 95.
The coin meter shall be able to short circuit two
signal lines for periods of up to 10 minutes. This
is to give the user time to load the machine,
choose a programme and start the programme
after putting the coins in.
"Insert coin" appears on the display when the
machine is started with the main power switch.