Operating The Stove Using A Thermostat; Thermostat Installation; Modes - Enerzone EUROZONE Owner's Manual

Table of Contents

Advertisement

OPERATING THE STOVE USING A THERMOSTAT

A thermostat will help you maintain a constant house temperature
automatically. A low voltage or 24 Volt thermostat is required. A fixed
wall mount or remote model can be used.

THERMOSTAT INSTALLATION

Unplug the stove from the power outlet.
Connect two thermostat wires to the terminal block located on the
lower right side of the back of the stove. To do so, loosen the two
screws and insert the wires in the terminals. Tighten the two
screws. (See Figure 40)
If you are using a wireless wall thermostat or a hand held
thermostatic remote control, you can locate the receiver behind the
stove's back panel, on the right side, just below the terminal block.
Most receivers are already equipped with quick-connect terminals.
Simply unplug the PC board wires connected to the back of the
terminal block and connect them directly with the receiver's
terminals. Location of the thermostat is very important to obtain
the best comfort and efficiency from you EUROZONE. The
thermostat should be mounted 50 inch from the floor on a wall
located 15 to 20 feet from the stove. You should avoid installing
directly in front of the stove to avoid cycling.(See Figure 41)

MODES

THERMOSTATIC MODE
To engage this mode, the thermostat icon
pushed upon starting the stove. The heat setting is then selected
using the "Heat Level" selector. When set in thermostatic mode,
the stove will automatically run at the heat level selected until the
set room temperature is reached. When that occurs, the stove will
switch to heat setting #1 (lowest) until the thermostat calls for heat
again. The convection blowers will also slow down to low speed.
When the thermostat calls for heat again, the stove will
automatically switch back to the selected heat level.
N.B.: If the room temperature remains stable and the thermostat
does not call for heat during at least 45 minutes, the stove will shut
down. When the thermostat calls for heat again, the stove will
start an ignition cycle. Once the ignition cycle is completed, the
stove will increase its feed rate to match the heat selected heat
level.
must be
17
Thermostat terminal
Figure 40
Thermostat terminal

Advertisement

Table of Contents
loading

Table of Contents