N.B.: It is possible to change the setting of your unit such that if the
thermostat does not call for heat after 45 minutes, the unit will remain at
the lowest heat setting (#1) but will not shut down (this is the PILOT ON
mode).
The stove will remain at the lowest heat level until the
thermostat calls for heat again.
following that logic, you need to change the setting to PILOT ON by the
pressing the following two buttons on the PC Board:
First press
, hold it, and then press
for a couple of seconds.
Once you do that, the letters P, I, L, O, T, O, N will appear on the PC
Board to let you know that you are in the "PILOT ON" mode. If you wish
to go back to the default thermostatic mode (i.e. the unit shuts down
after 45 minutes if the thermostat does not call for heat), simply press
the same two buttons again for a couple of seconds. The letters P, I, L,
O, T, A, U, T, O will appear on the PC Board to let you know that you
are in the "PILOT AUTO" mode.
NOTE: When in thermostatic mode:
You should not operate the manual control or play with the
temperature setting.
YOUR THERMOSTAT SHOULD BE INSTALLED BY AN
AUTHORIZED DEALER OR QUALIFIED TECHNICIAN.
If you prefer that your unit runs
. Hold the two buttons
Thermostat location
18
Figure 41