Continuity Check; Peak Hold Measurements - IDEAL ND 2366-1 Manual

Commercial contractor grade multimeter
Table of Contents

Advertisement

Continuity Check

Circuit Connection:
True RMS
To Verify Continuity:
A continuity test ensures that all circuit connections are intact.
1. Plug the black test lead into the COM port and the red test
lead into the °C°F V Hz port.
2. Set the rotary switch to the
position.
3. Press the blue button until
is shown in the display.
4. Connect the test leads to the circuit to be measured. The
buzzer will sound if the resistance of the circuit measured is
lower than 30 .
17

Peak Hold Measurements

True RMS
Function
Range Accuracy
Function Range Accuracy
DC Voltage 400mV Unspecified AC Voltage 400mV Unspecified
4V
±(1.5% +300)
4V
40V
±(1.5% +60)
40V
400V
400V
1000V
750V
DC Current 40mA ±(3% +60)
AC Current 40mA ±(3% +60)
400mA
400mA
10A
±(1.5% +60)
10A
In current and voltage measurements, the REL
performs a peak hold function. The peak hold mode must be
calibrated prior to use. To calibrate the peak hold, press the key
until the meter displays "CAL". Short the test leads to calibrate.
18
±(1.5% +300)
±(1.5% +60)
±(1.5% +60)
button