IDEAL ND 2366-1 Manual page 3

Commercial contractor grade multimeter
Table of Contents

Advertisement

Overload Protection
Function
Overload Protection
VAC & VDC
1000V
AAC & ADC
1A/500V
16A/500V
Ohms ( )
600VAC/600VDC
Diode
600VAC/600VDC
Continuity
600VAC/600VDC
Unit of Measure Multipliers
For your reference, the following symbols are often used to
make measurement easier:
Symbol
Verbal
Multiplier
M
mega
x 1,000,000
k
kilo
x 1,000
m
milli
÷ 1,000
µ
micro
÷ 1,000,000
Auto Power Off (APO)
The APO sign on the LCD panel indicates the meter is working
in the Auto Power Off mode. If the meter idles for more than 30
minutes, the meter automatically turns the power off. When this
happens, the state (non-logic measurement) of the meter is
saved, the meter can be turned back on by pushing any key
switch or changing the rotary switch. The meter will give an
alarm in 15 seconds before the meter automatically turns the
power off. To disable the auto power off function, power up the
meter while pressing either the range, REL
switch.
5
True RMS AC Volt
True RMS
Range
400mV
4V
40V
400V
750V
AC Conversion Type: AC conversions are AC-coupled, true
RMS responding, calibrated to the RMS value sine wave input.
or min/max
Input and Impedance: 10M less than 100 PF.
Crest Factor: +1.5% additional error for C.F. from 1.4 to 3
To Measure True RMS AC Voltage:
1. Plug the black test lead into the COM port and the red test
lead into the °C°F V Hz port.
2. Set the rotary switch to the V position.
3. Push the blue button until
4. Connect the meter in parallel with the load or circuit.
5. Measure AC Voltage.
Circuit Connection:
Resolution
Max Display
Accuracy
0.1mV
400.0
±(2.0% +8)
40Hz to 60Hz
1mV
4.000
±(1.3% +5)
40Hz to 1kHz
10mV
40.00
±(1.3% +5)
100mV
400.0
40Hz to 1kHz
1V
750
+3.0% additional error for C.F. from 3 to 4
˜
is shown on the display.
AC
6