Regulation To Different Kinds Of Gas - Electrolux EKC5614 Instruction Book

Mixed fuel cooker
Table of Contents

Advertisement

REGULATION TO DIFFERENT KINDS OF GAS

Your cooker is designed to work with natural
gas, propane or butane. It is not designed for
butane or propane air.
Connection to the LPG bottle should be carried
out in accordance with the enclosed picture.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by an
authorised Service Engineer.
For changing the gas type it is necessary to:
replace the nozzles (hob);
adjust the minimum level (hob);
check the gas connection;
Stick the label supplied with the
appliance (in the nozzles bag) corresponding
to the gas type utilised.
NOM.
Reduced
POWER
BURNERS
(kW)
3,00
RAPID
1,00
AUXILIARY
NOM.
Reduced
POWER
BURNERS
(kW)
3,00
RAPID
3,00
2,60
1,00
1,00
AUXILIARY
0,85
SPECIFICATION NOZZLES
Cat : II
By-pass
(mm)
power
TYPE OF GAS
(kW)
Natural gas G20
0,72
0,42
Butane
Propane
Natural gas G20
0,35
0,29
Butane
Propane
Cat : II
By-pass
(mm)
power
TYPE OF GAS
(kW)
0,72
Natural gas G20
0,72
0,42
Butane
0,63
Propane
0,35
Natural gas G20
0,35
0,29
Butane
0,31
Propane
B
A
A – Distributor pipe
B – Nut 1/2"
C – Gasket
D – Hose nipple
E – Elbow
2E+ 3+
PRESSURE
(mbar)
20
G30
28-30
G31
37
20
G30
28-30
G31
37
2H 3B/P
PRESSURE
(mbar)
20
G30
30
G31
30
20
G30
30
G31
30
C
E
C
D
NOZZLE
Cons.
DIAM.
(mm)
3
m
/h
g/h
1,19
0,267
-
0,88
-
218,1
0,88
-
214,2
0,70
0,095
-
0,50
-
72,7
0,50
-
71.4
NOZZLE
Cons.
DIAM.
(mm)
3
m
/h
g/h
1,19
0,267
-
0,88
-
218,1
0,88
-
185,7
0,70
0,095
-
0,50
-
72,7
0,50
-
60,7
7