Low Voltage Control - Da-Lite TENSIONED COSMOPOLITAN ELECTROL Instruction Book

For sizes up to 10'x10'
Table of Contents

Advertisement

TENSIONED COSMOPOLITAN
240V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN

LOW VOLTAGE CONTROL

BLUE (COMMON)
BROWN (HOT)
240VAC 50HZ
GREEN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
SCREEN ADJUSTMENT FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL
The screen surface travel is stopped automatically in the fully opened and closed positions by limit switches that are
properly adjusted at Da-Lite. The screen should not be adjusted for more or less drop. The fabric cables are adjusted for
proper vertical and lateral tension at Da-Lite.
Should the picture surface get out of adjustment and it be necessary to adjust picture surface drop, proceed in the
following manner.
NOTE: Use a small flat screwdriver or 5/32" Allen wrench to make adjustments.
SETTING THE DOWN LIMIT POSITION
TO REDUCE SCREEN DROP:
Turn the white limit switch screw (Figure 3) clockwise to decrease the amount of screen drop. Run the screen
down to test the stop position. If the screen drops too far, raise the screen about one foot and adjust the limit
switch again. Repeat until the desired position is set.
TO INCREASE SCREEN DROP:
Turn the white limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down to
test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit
switch again. Repeat until the desired position is set.
s
!
CAUTION: Do not adjust for more drop than what was ordered. At least 1-1/2 wraps of fabric must remain on the roller. This
screen comes standard with 12" black at the top.
NOTE: The slat bar will not retract completely into the case. DO NOT adjust the up limit travel any higher than the factory
preset position or damage may occur.
ELECTROL
INSTALLATION
®
®
GREEN
GROUND TO CASE
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
RJ9
SPLITTER
DRY CONTACTS
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the
switch or provide a 4-conductor connection that is
accessible.
4
CONNECT SUPPLIED
RJ9 CABLE TO
SPLITTER AND
SWITCH, OR USE 4
CABLE CONDUCTOR
TO CONNECT TO
LOW-VOLTAGE WALL SWITCH
SCREW TERMINALS.
UP
RJ9
STOP
DOWN
FRONT
FIGURE 6
UP DN
GND +5V
3-POSITION
RJ9
SWITCH
BACK

Advertisement