Gasket Replacement; Fireplace Installation; Locating The Wfp-75 - HearthStone WFP-75 Owner's Manual

Wood fireplace
Hide thumbs Also See for WFP-75:
Table of Contents

Advertisement

2.3.9 Gasket Replacement

Remove the door from the unit and lay it on a clean, non-abrasive surface. To replace the
gasket around the door frame, first remove the old gasket and adhesive. Make sure that
the surface is totally clean before applying new adhesive or adhesion problems may result.
Apply the adhesive (supplied with the replacement gasket) in the gasket channel and install
the new gasket with a gentle pressure.
To replace the glass gasket, follow the steps in section 2.3.7. The proper replacement
gaskets are available from your HearthStone dealer in the following dimensions:
GASKET
DOOR
GLASS

2.4 FIREPLACE INSTALLATION

2.4.1 Locating the WFP-75

A. The best location to install your fireplace is determined by considering the location of
windows, doors, and the traffic flow in the room where the fireplace is located, allowing
space in front of the unit for the heart extension and the mantel, and taking into consid-
eration the location of the hot air ducts (optional), outside air kit and chimney. If possible,
you should choose a location where the chimney will pass through the house without cut-
ting floor or roof rafters.
B. Usually, no additional floor support is needed for the fireplace. The adequacy of the floor
can be checked by first estimating the weight of the fireplace system. Weights are given
in the appendix. Next, measure the area occupied by the fireplace which is normally
37.75" × 24.75" (96 cm x 63 cm). Note the floor construction and consult your local build-
ing code to determine if additional support is needed.
C. The WFP-75 may be installed directly on the floor or on a raised combustible or non
combustible base (see figure 5). That base must be at least equal (or exceed) the height
of the floor protection. For more information regarding the installation on a raised base,
refer to the "Hearth Extension Requirements" section of this manual. Please take note
that a minimum of 7 feet (2.15 m) measured from the base of the appliance to the ceiling
is required (see figure 6).
Hearthstone Quality Home Heating Products, Inc ®
LENGHT
DIMENSION
84"
ROUND 1" ROPE
78"
ROUND 1/4" ROPE
13
WFP-75 Model 8410

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8410

Table of Contents