plastic wrapping around the flexible pipe is not in contact with the fireplace;
3. Attach the flexible pipe to the fan's air inlet using the collars provided (figure 33);
4. Attach a flexible pipe to the fan's air outlet and route the flexible pipe to the chosen
location. The ducting system can be installed either in an upper room or in a lower
room;
5. At that point, the flexible pipe can be attached to any air distribution grille.
6. Make the electrical connections to the PC Board as explained with the forced air kit
owner's manual.
Since the forced air kit requires electricity, make sure that the connections to the fan have
been made according to the local codes and comply with their requirements (see instruction
provided with the kit).
Hearthstone Quality Home Heating Products, Inc ®
Figure 32
Figure 33
Figure 34