Advertisement

Error Code
Error Message
305*
Data Link failure
307
LAN No Carrier
308
IP-GW LAN Loop
back Error
309
IP-GW Core Data
Link Error
310*
Port Link Failure
320
IP-GW H.323
Dummy Call Test
Error
321
IP-GW
Gatekeeper Error
322
IP-GW
Gatekeeper
Registration Error
323
IP-GW SDRAM
Failure
324
IP-GW DPRAM
Failure
325
IP-GW LAN Chip
Failure
326
IP-GW Stop
PROBABLE CAUSE
Data link between the CS and
Hybrid IP-PBX failed
Data link between the
network and IP-GW card
failed
IP-GW card not connected to
the LAN
Detection of IP-GW LAN
Loop back Test error
Detection of IP-GW Core data
Link error
Voice Processing System
malfunction
Ports defective on optional
service card: DLC
Detection of IP-GW H.323
Dummy Call Test error
Detection of Gatekeeper
access error
Gatekeeper Registration is
failed
Detection of IP-GW SDRAM
error
Detection of IP-GW DPRAM
error
Detection of IP-GW LAN Chip
failure
IP-GW is stopped from
remote maintenance PC
SOLUTION
Check the connection between the CS
and Hybrid IP-PBX
Check the connection between the
network and IP-GW card
Check the connection between the
LAN and IP-GW card
Replace the corresponding optional
service card
Collect the log data of IP-GW (refer to
the Installation Manual for IP-GW card)
Press the Reset Button
Collect the log data of IP-GW (refer to
the Installation Manual for IP-GW card)
Check the Voice Processing System
See if the corresponding optional
service card is installed properly
Replace the corresponding optional
service card
Replace the corresponding optional
service card
Collect the log data of IP-GW (refer to
the Installation Manual for IP-GW card)
Check the IP address setting of
Gatekeeper
Check whether the Gatekeeper is
connected to the network and work
properly
Check the route to the Gatekeeper
Check the Gatekeeper setting
Replace the corresponding optional
service card
Replace the corresponding optional
service card
Replace the corresponding optional
service card
Collect the log data of IP-GW (refer to
the Installation Manual for IP-GW card)
This information is logged when IP-GW
is stopped from remote maintenance
PC
Installation Manual
4.1 Troubleshooting
147