Danfoss DHP-AX User Manual page 24

Table of Contents

Advertisement

5.1.2
Sub-menu HEAT CURVE
In the HEAT CURVE menu the settings that affect the
indoor temperature are made. For further informa-
tion, see section "2 About your heat pump".
Menu text
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE - 5
HEAT STOP
REDUCTION
ROOM FACTOR
(Only displayed if
a Room sensor is
installed.)
POOL
(Only displayed if
an Expansion card is
installed)
DHP-AX – 24
Description
The set value indicates the supply line
temperature of the water that is trans-
ported to the heating system at an out-
door temperature of 0°C.
Sets the lowest permitted supply tempe-
rature.
Sets the highest permitted supply tem-
perature.
Used to adjust the heat curve at an out-
door temperature of +5°C.
Used to adjust the heat curve at an out-
door temperature of 0°C.
Used to adjust the heat curve at an out-
door temperature of -5°C.
This function stops all production of
heat when the outdoor temperature is
equal to, or higher than, the set heat stop
value.
The temperature can be lowered using
an outside timer. The control computer
lowers the indoor temperature using the
set value.
Determines how large an impact the
room temperature is to have when cal-
culating the supply temperature. For
underfloor heating we recommend a set-
ting between 1-3 and for radiator heating
between 2-4.
The temperature in the pool is controlled
by a separate sensor regardless of the
heating and hot water system.
VUBMI102
HEAT CURVE
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE -5
HEAT STOP
Adjusted by:
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
By the customer, if
necessary.
Factory setting: 2 (inter-
val: 0 - 4)
(0 = no impact,
4 = large impact)
By the customer, if
necessary.
40°C
22°C
70°C
0°C
0°C
0°C
17°C