Function No.
Function
Parameter or
Setting range
Calf01
Unit
0
4
to
Decimal
Calf02
point
0
5
to
position
Calf03
Minimum
1
6
division
to
Calf04
Weighing
1
999999
capacity
to
Zero
Calf05
adjustment
0
100
to
range
Description
Unit of the weight value
0: None
1: g
2: kg
3: t
4: lb (USA version)
Decimal point position of the weight value
0: None 123456
1
1: 10
12345.6
2
2: 10
1234.56
3
3: 10
123.456
4
4: 10
12.3456
5
5: 10
1.23456
Minimum division (d) of the weight value
1: 1
2: 2
3: 5
4: 10
5: 20
6: 50
Weighing
capacity
instrument
Weighing is possible up to the value of this
setting plus 8 d. If the value exceeds this,
overflow will occur and will not be
displayed.
The decimal point position is the same as
Calf02
the setting of
Range to enable zero adjustment by the
ZERO key
Expressed in percent of the weighing
capacity with the calibration zero point as
the center.
For example, if this is set to 2, the value in
the range of ±2% of the weighing capacity
with the calibration zero point at the center
will set to zero.
Page 23
of
the
weighing
.
Default
value
2
0
1
20000
2
AD-4408A