Installing The Logset; Wiring - Montigo M38BV-ST Installation & Operation Manual

See-thru b-vented gas fireplace
Hide thumbs Also See for M38BV-ST:
Table of Contents

Advertisement

M38BV-ST B-Vented Fireplace
Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fan Plug
Receptacle
Grnd Screw
Limit
Wall
Switch
Switch
Figure 5. Wiring for the M38BV-ST-I with Honeywell gas control and
Fans
The M38BV-ST is equipped with 4 fans for circulating heat into
the living space. Installations in Canada must be in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must be in accordance with local codes
or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
NOTE:
If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.
L1-WH
G
L2-BLK
Figure 6a. Wiring for fans.
Page 
Installation

Wiring

M38BV-ST-I
Junction Box Cover
Fuse
Junction Box
115VAC
24VAC
40 VA
Transformer
pilot.
Fan motors
115/1/60 Supply
G
L1 L2
Figure 6b. Wiring schematic for fans.
Installing the Log Set
The M38BV-ST is supplied with five (5) fibre logs. To install, simply
Black
place log "A's" rectangular shaped extension into the log mounting
White
Green
slot located on rear wall of the burner assembly. Place log "B" onto
front log slots of the burner assembly. Place log "C" and log "D" onto
the mating positions as shown in Figure 7a below. When log set is
installed it should look like Figure 7b.
Log 'D'
Figure 7a. Log Installation - Step 1.
Figure 7b. Log Installation - Step 2.
If logs are not placed properly, excessive
sooting will result.
Log 'C'
Log 'B'
Log 'A'
Log 'E'
WARNING
:

Hide quick links: