Finishing Around the Fireplace

Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in Figure 4a. Side wall clearances are 0".
Combustible surrounds may be installed with 0" clearance to the side
of the fireplace as shown in Figure 4b.
Fireplace Facing
When selecting the finish material for your fireplace, it is important
to remember the following: BRASS TRIMS MUST NOT BE OB-
STRUCTED IN ANY WAY - to do so restricts the air supply for
the control compartments and heat exchanger it also prevents
access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.
Combustible construction
allowed in shaded area.
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
12
11
10
9
8
7
6
5
Top of fireplace
Figure 4a. Combustible mantles and facings.
Installation
Combustible Facing
14" min.
to combustibles
6" min.
4
3
2
1
0
M38BV-ST B-Vented Fireplace
Mantels & Surrounds
NOTE: Mantel clearances shown are for fire hazard prevention.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above nor-
mal room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause melt-
ing, deformation, discoloration or premature failure of T.V. and radio
components.
Painting:
1 1/2" clearance to combustibles
(0" to standoffs on sides)
Combustible construction
allowed in shaded area.
Figure 4b. Combustible surrounds.
Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and ap-
ply a quality Alkyd sealer prior to the applying of latex paints. This is
to prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.