Questions? Email us at fireplaces@montigo.com or visit our website at www.montigo.com. Installation Operation & Maintenance Direct-Vented Gas Fireplace Check local codes read instructions prior to installation. Leave this manual with the owner.
Propane at 28,000 BTU/H (8.20 Kilowatts) max. input, and Vertical Venting Runs ........8 21,800 BTU/H (6.40 Kilowatts) min. input Construction around the fireplace The Montigo warranty will be voided by, and Montigo disclaims any Facing ............10 responsibility for, the following actions: Mantels and Surrounds ........10 Modification of the fireplace and/or components including Direct- Installing the Logset .............
Panorama Direct Vented Fireplace Installation Installing The Fireplace Shell The fireplace may be installed in any location that maintains clearances Framing to air conditioning ducts, electrical wiring and plumbing. Safety, as well Unprotected combustible walls which are perpendicular to the fireplace as efficiency of operation, must be considered when selecting the opening, must not project beyond the shaded area shown in Figure fireplace location.
Use only (Use of other parts will applicable installation codes. void the Montigo warranty, and may impede the operation of the fireplace.) All joints must be secured with a minimum of two screws per joint Vent terminations must not be recessed in walls or siding Horizontal runs must be supported by a minimum of two supports per horizontal run.
Panorama Direct Vented Fireplace Installation Vent Terminations Attach to the faceplate of the termination using four sheet metal screws. Installing Terminations with Built-In Frames Frame the termination opening to 11" x 11". Fasten the termination to the studs using a minimum of 4 screws. PTO-3F PTKOG Figure 5d.
Panorama Direct Vented Fireplace Installation Direct Vent Installation Long Vent Runs: For longer or more complex vent runs, vertical lift is required. First Vent systems that terminate through a wall may comprise up to six ensure that the planned run is acceptable using the Vent Graph. Plan different components: out the required components using the chart above.
Page 7
Panorama Direct Vented Fireplace Installation Installation Installation Installation Installation Vertical Vent Installations A maximum of two offsets (each offset has two 90° bends) may be made if the length of the offsets does not exceed 25% of the vertical vent Vertical Terminations must be installed: height, when measured center to center of piping.
Panorama Direct Vented Fireplace Installation Finishing Around the Fireplace Mantels & Surrounds Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project NOTE: Mantel clearances are for fire hazard prevention to combus- beyond shaded area shown in Figure 13a.
Panorama Direct Vented Fireplace Installation Wiring 115/1/60 Supply Gas Control and Pilot Wiring M38DV-PRC-I L1 L2 Honeywell (Q3450) Fan Switch Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Figure 15b. Removing and Installing the Gas Control Junction Box Cover Connector Fuse Inner Doors...
Panorama Direct Vented Fireplace Installation Operation Installing the Logs and Embers Lighting Instructions Bottom Logs See Pages 11-12. The M38DV-PRC is supplied with five (5) fibre logs. The two large Burner Adjustment bottom logs (logs are mounted on the burner grate by placing them into the slots.
Panorama Direct Vented Fireplace Operation - Model M38DV-PRC M38DV-PRC with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by If you cannot reach your gas supplier, call the Fire hand.
Panorama Direct Vented Fireplace Operation - Model M38DV-PRC-I M38DV-PRC-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
Page 13
Panorama Direct Vented Fireplace Maintenance Gas Control Valve CAUTION • Fireplace gas control must be in the “OFF” position and pilot and main burners extinguished when cleaning appliance with Secondary Limit T h e rm o co u p le P o w e r Ve n t S a fe ty S w itch a vacuum.
Panorama Direct Vented Fireplace Maintenance Troubleshooting M38DV-PRC Troubleshooting M38DV-PRC-I The following is a troubleshooting chart of possible problems: PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adjustment screw on the Before Troubleshooting, Familiarize Yourself With front of the gas control valve. Flame is The Startup And Checkout Procedure.
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
Page 16
Panorama Direct Vented Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or M = clearance to mechanical air supply inlet balcony [16 inches (41 cm) minimum] [*6 feet (1.8 m) minimum] N = †...
Page 17
Panorama Direct Vented Fireplace Notes G0204 Page 17...