Installation Operation & Maintenance ME34-DV Modular Gas Fireplace Warning: For Your Safety: Check local codes and Improper installation, adjustment, altera- Do not store or use gasoline read all instructions tion, service or maintenance can cause injury or other flammable vapors prior to installation.
M34 Series Modular Fireplaces allow quick and easy upgrades in Installation the future. The ME34-DV can be upgraded to a Wildfire Burner or a Installing the Fireplace Shell .......... 3 25,000 BTU dual burner. Contact your dealer for more information.
For Rear Vent models (ME34DR), the minimum clearance from the top of the fireplace to a shelf is 7". For The ME34-DV clearances to combustible materials are: Top Vent models (ME34DT), the minimum clearance is 13". (Minimum Top - Rear Vent* 7"...
Installation Installing The Gas Line Vent Installation The gas line must be installed before finishing the ME34-DV Fire- This section covers the installation of direct venting and terminations. place. Natural Gas requires a minimum inlet gas supply pressure of Installation Requirements 5.5"...
Page 5
ME34-DV Modular Fireplace Installation Installing Terminations with Built-In Frames Attach to the faceplate of the termination using four sheet metal MTO-3F MTKOG Frame the termination opening to 11" x 11". Installing Heat Guards over Terminations Fasten the termination to the studs using a minimum of 4 Ensure that the two long mounting brackets are facing the bot- screws.
Top Vent Venting Runs Heat Shields Due to high flue temperatures, heat shields For the ME34-DV Top Vent, there are two types of installations: A) are required on all 34 Series Modular Direct Through-The-Wall Installations and B) Vertical (Through-The-Roof) Vent installations (except those with vertical Installations.
ME34-DV Modular Fireplace Installation Top Vent Example 1: 150" max. For our shortest venting configuration use components A and F (see 30" max. Figure 9a). H e a t S h i e l d T e r m i n a t i o n...
ME34-DV Modular Fireplace Installation Top Vent B. Vertical (Through-The-Roof) Installations Vertical Terminations must be installed: A maximum of two offsets with 90° bends may be made and shall • minimum 2' (two feet) above the highest point where not exceed total length of 25% of the vertical vent height, when vent passes through the roof.
The height from the hearth to the center of the termination is 26 T e r m i n a t i o n 1/8". ME34-DV Rear Vent versions are supplied with an 18" exten- H e a t S h i e l d sion pipe (EXT-18) with female/female connections.
Rear Vent Installation Of Rear Vent DV B. Multi-Elbow Installations ME34-DV Rear Vent versions are supplied with an EXT-18 (female/ For more diffiicult installation situations, the ME34-DV Rear Vent female) section. In addition, the following venting components are may be installed with 2 - 90° elbows and up to 15' of horizontal run.
T r a n s f o r m e r L i m i t W a l l S w i t c h S w i t c h Figure 22. Wiring for the ME34-DV-I with Honeywell gas control and pilot. Page 11 Part No. XG0105A...
Installing the Logs: All 34 Series Modular fireplaces feature an optional fan kit for circulat- The ME34-DV is supplied with four (4) fibre logs. Logs 'A' and 'B' are ing heat into the living space. factory installed on the mounting slots. They should be positioned as shown in figure 24a.
ME34-DV Modular Fireplace Installation Removing and Installing Removing and Installing the Insert the Door You may remove the insert to protect it from theft and damage dur- Removing the door surround: ing construction. The door surround is held in place by two metal clips at the top, and 1.
Page 14
ME34-DV Modular Fireplace Operation - Model ME34-DV ME34-DV with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Page 15
ME34-DV Modular Fireplace Operation - Model ME34-DV-I ME34-DV-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Doors and logs can get very hot. Handle only when cool. Raising or lowering the Flame Height The ME34-DV fireplace is equipped with an adjustable rear burner, General allowing you to raise or lower the flames. The main burner can be turned off using this method, allowing the fireplace to operate safely ...
Page 17
ME34-DV Modular Fireplace Maintenance Troubleshooting Gas Control Valve ME34-DV-I P o w e r G e n e r a t o r P i l o t A d j u s t m e n t S c r e w...
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.