Installation Operation & Maintenance M38DV-PFC Peninsula Direct-Vented Gas Fireplace Check local codes and read all Warning: For Your Safety: instructions prior to installation. Improper installation, adjustment, Do not store or use alteration, service or maintenance gasoline or other flam- Installer: Leave this manual ...
M38DV-PFC Peninsula Gas Fireplace Introduction Table Of Contents The M38DV-PFC is a direct-vented, 3-sided Gas Fireplace with an adjustable center burner and air-circulating fans. It is available in two Introduction ................2 models: Installation ................3 - 12 Model M38DV-PFC (continuous pilot) ...
0", but we recommend a clearance of 1/2" - 1" to allow for settling of the building. 13 3/4 1 1/2 24 5/8 End View Figure 1. Fireplace dimensions. Clearances The M38DV-PFC clearances to combustible materials are: Top* 0" Back 0" Floor 0" Mantle** 6"...
Installation Installing The Gas Line Vent Installation The gas line must be installed before finishing the M38DV-PFC fire- This section covers the installation of direct venting and terminations. place. Natural Gas requires a minimum inlet gas supply pressure of For a detailed diagram of allowed termination locations, see Appen- 5.5"...
M38DV-PFC Peninsula Gas Fireplace Installation Venting Runs Installing Terminations with MSR Frames 1. Frame the termination opening to 12" x 12". If your installation requires more than 12" of horizontal venting, some vertical lift is required. Use the vent graph below to determine an 2.
M38DV-PFC Peninsula Gas Fireplace Installation Direct Vent Installation Vent systems that terminate through a wall may comprise up to six 12" max. horizontal different components: (with no vertical lift) A - Termination PTKO-2 (2" length) Extension PTKO-5 (5" length) PXT-5 / -10 PTKO-9 (5"...
Page 7
M38DV-PFC Peninsula Gas Fireplace Installation Vertical Vent Installations A maximum of two offsets with 45° bends may be made if the length of the offsets does not exceed 25% of the vertical vent height, when Vertical Terminations must be installed: ...
M38DV-PFC Peninsula Gas Fireplace Installation Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the Mantels & Surrounds top and on the front of the fireplace provided that they do not project NOTE: Mantel clearances are for fire hazard prevention to combus- beyond shaded area shown in Figure 13a.
Junction Box Cover Connector Fuse Bottom Logs Junction Box The M38DV-PFC is supplied with five (5) fibre logs. The two large Fan Plug Receptacle bottom logs (logs "A" and "B") are mounted on the burner grate by placing them into the slots.
The inner (combustion) doors are located behind the outer decorative doors. To remove the inner doors, simply unscrew the nine (9) ma- The M38DV-PFC is equipped with an adjustable burner, allowing you chine screws on the top, bottom and side of the door. (See figure 17).
Page 11
M38DV-PFC Peninsula Gas Fireplace Operation - Model M38DV-PFC M38DV-PFC with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by Department. hand. When lighting the pilot, follow these instructions C. Use only your hand to push in or turn the gas control exactly. knob. Never use tools. If the knob will not push in or B. BEFORE LIGHTING smell all around the appliance turn by hand, don't try to repair it, call a qualified serv- area for gas.
Page 12
M38DV-PFC Peninsula Gas Fireplace Operation - Model M38DV-PFC-I M38DV-PFC-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition sys- If you cannot reach your gas supplier, call the tem that lights the pilot burner automatically. Do Fire Department.
Page 13
M38DV-PFC Peninsula Gas Fireplace Maintenance Gas Control Valve CAUTION • Fireplace gas control must be in the “OFF” position and pilot and main burners extinguished when cleaning appliance with Secondary Limit Thermocouple Power Vent Safety Switch a vacuum. Connection Generator •...
M38DV-PFC Peninsula Gas Fireplace Maintenance Troubleshooting Troubleshooting M38DV-PFC M38DV-PFC-I The following is a troubleshooting chart of possible problems: HONEYWELL SV 9500 /SV9600 PROBLEM CORRECTIVE ACTION Troubleshooting Sequence Noisy Pilot Flame Locate pilot adjustment screw on the NOTE: front of the gas control valve. Flame Before Troubleshooting, Familiarize Yourself With The Startup And Checkout Procedure.
Page 15
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
M38DV-PFC Peninsula Gas Fireplace Appendix A - Spare Parts Model M38DV-PFC 5/16 A lum . Tub ing Model M38DV- PFC-I 5/16 A lum . Tub ing 1. Fan Motor (MBL-1) 6. Termination (PTKO Series) 2. Power Cord (PPCH-4) 7. Heat Guard (PTKOG) 3.
Page 17
M38DV-PFC Peninsula Gas Fireplace Appendix B - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, [*6 feet (1.8 m) minimum] or balcony [16 inches (41 cm) minimum] clearance above paved sidewalk or a paved driveway located on †...
Page 18
XG0202 Rev. 07/99 Canadian Heating Products Inc. Montigo Del Ray Corp. Surrey, BC V3W 2V6 Ferndale, WA 98248...