Fan Wiring

Wiring for the optional Fan and Blower Kits
All 38 Series fireplaces may be equipped with optional fan or blower
kits for circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included
with the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
L1-WH
G
L2-BLK
f i r e - p a r t s . c o m
Quick Connect
plug to motor
Figure 14a. Wiring for optional air circulating fan kit.
115/1/60 Supply
G
L1 L2
Figure 14b. Wiring schematic for optional fan kit.
Part No. XM0500
Installation
Installing the Log Set
Installing the Logs:
The E38-PV is supplied with five (5) fibre logs. Logs 'A' and 'B' are
factory installed on the mounting slots. They should be positioned as
shown in figure 15a. Place logs "C","D" and "E" onto the mating
positions as shown below in figure 15b.
Figure 15a. Log 'C' is positioned in its mating position with the'y'
toward the back of the fireplace. Logs 'A' and 'B' shown in
factory-installed positions.
Log 'D'
Embers
Figure 15b. Completed log installation. Logs 'D' and 'E' are placed in
their mating positions, and embers are in place.
Placing the Embers:
The E38-PV is supplied with a small bag of embers. Place the ember
material along the middle of the burner between the flame shaper and
log 'A'. Do not let the ember material fall behind the burner tube.
If logs are not placed properly, excessive sooting will result.
n
The surface of the logs will crack due to the heat from the
n
flames. This is a normal occurance.
E38-PV Gas Fireplace
Log 'B'
Log 'C'
Log 'A'
Log 'E'
Flame Shaper
NOTES
:
Page 9
Page 9
Page 9
Page 9
Page 9