PF
( the next response demonstrates reversing the prompting order )
XON/XOFF protocol [Y,N] = Y? ^ <CR>
Stop Bits [1,2] = 2? .<CR>
OK to proceed (y/n)? Y
CPU32Bug>

3.24.3 Port Format Parameters

The port format parameters are:
Port base address – When assigning a port, there is a set base address option. This
allows the user to adjust the base address for different hardware configurations.
Entering no value selects the default address.
Baud rate – Select the baud rate: 110, 300, 600, 1200, 2400, 4800, 9600, 19200.
Parity type – Set parity: even (E), odd (0), or disabled (N).
Character width – Select 5-, 6-, 7-, or 8-bit characters.
Number of stop bits – Only 1 and 2 stop bits are supported.
Automatic software handshake – Current drivers have the capability of responding to
XON/XOFF characters sent to the debugger ports. Receiving a XOFF causes a driver
to cease transmission until a XON character is received. None of the current drivers
utilize FIFO buffering, therefore, none initiate an XOFF condition.
Software handshake character values – The values used by a port for XON and XOFF
may be defined as any 8-bit value. ASCII control characters or hexadecimal values are
accepted.
Not all combinations of parity type, character width, and stop bits
are supported for the BCC "SCI" port, 00. See Appendix C for
details.