Set Stop Address (Mt C) - Motorola M68CPU32BUG User Manual

Debug monitor
Table of Contents

Advertisement

MT C
6.5.3 Set Stop Address
CPU32Diag>MT C [new value]
MT C allows the user to select the stop address used by all of the memory tests. The stop address
is the address where testing terminates, so the stop address must be set to the last address +1.
EXAMPLE
If the user supplied the optional new value, then the display appears as follows:
CPU32Diag>MT C [new value]<CR>
Stop Addr.=<new value>
CPU32Diag>
If a new value was not specified by the user, then the old value is displayed and the user
is allowed to enter a new value.
The default is Stop Addr.=00010000, which is the end of on-board
RAM.
CPU32Diag>MT C
Stop Addr.=<current value> ?[new value]<CR>
Stop Addr.=<new value>
CPU32Diag>
This command may be used to display the current value without changing it by pressing a
carriage return <CR> without entering the new value.
CPU32Diag>MT C
Start Addr.=<current value> ?<CR>
Start Addr.=<current value>
CPU32Diag>
If a new value is specified, it is truncated to a longword boundary
and, if less than the value of the start address, is replaced by the
start address. The stop address is never allowed to be lower in
memory than the start address. These changes occur before another
command is processed by the monitor.
M68CPU32BUG/D REV 1
Set Stop Address
NOTE
NOTE