Bosch MIC IP PSU User Manual page 66

Mic series ip power supply
Table of Contents

Advertisement

66
en | Configuration using a Web browser
are to be possible, for example when initiating connections via higher-ranking systems such as
Bosch Video Management System, you can store a general password here. The encoder can
use this general password to connect to all remote stations protected with the same
password. In this case, proceed as follows:
1.
2.
3.
4.
NOTICE!
If you enter the destination IP address 0.0.0.0 for destination 10, the encoder will no longer
use this address for the tenth attempt at automatic connection in the event of an alarm. The
parameter is then used only to save the general password.
Video transmission
If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer
protocol. For use in a local network, select UDP.
CAUTION!
Please note that in some circumstances, a larger bandwidth must be available on the network
for additional video images in the event of an alarm, in case multicast operation is not
possible. To enable multicast operation, select the UDP option for the Video transmission
parameter here (see Section 4.45 Multicast, page 77).
Stream
Select the stream for transmission in case of an alarm.
Remote port
Depending on the network configuration, select a browser port here. The ports for HTTPS
connections will be available only if the On option is selected in the SSL encryption
parameter.
Video output
If you know which unit is being used as the receiver, you can select the analog video output to
which the signal should be switched. If the destination unit is unknown, it is advisable to
select the First available option. In this case, the image is placed on the first free video output.
This is an output on which there is no signal. The connected monitor only displays images
when an alarm is triggered. If you select a particular video output and a split image is set for
this output on the receiver, you can also select from Decoder the decoder in the receiver that
is to be used to display the alarm image.
NOTICE!
Refer to the destination unit documentation concerning image display options and available
video outputs.
Decoder
Select a decoder of the receiver to display the alarm image. The decoder selected has an
impact on the position of the image in a split screen. For example, you can specify that the
upper-right quadrant should be used to display the alarm image on a VIP XD by selecting
Decoder 2.
F.01U.265.804 | 1.6 | 2012.08
In the Number of destination IP address list field, select 10.
Enter the address 0.0.0.0 in the Destination IP address field.
Enter your chosen password in the Destination password field.
Define this password as the user password for all remote stations to which a connection
is to be possible.