Secondary Non Decoded Output Laser Emulation
Use this selection when connecting to a secondary terminal with integral decod-
ing. This also sets the transmission rate to 36 scans per second and the polar-
ity to white high.
Non Decoded Output
Non Decoded Output Laser Emulation
Transmission Rate
The Transmission Rate is limited by the terminal's ability to receive data without
dropping characters. Default = 36 scans/second.
* 36
100
Non Decoded Output Laser Emulation Polarity
The Polarity can be sent as standard with white bars high, or reversed with
black bars high. Default = White High.
* White High
Black High
6 - 2