Error Code Table - Maytag UMV1152CA Manual

2006 over-the-range domestic microwaves
Hide thumbs Also See for UMV1152CA:
Table of Contents

Advertisement

Troubleshooting Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to microwave oven and discharge the
high-voltage capacitor before servicing, unless testing requires power.

Error Code Table

Error Code
SE
Keypad shorted 10 seconds or longer.
E03
Convection motor or convection heater open.
E11
Gas sensor open error.
E12
Gas sensor short error.
E13
T1 Max time error (oven did not preheat properly).
E21
Thermal sensor open error.
E22
Thermal sensor short error.
PREHEAT did not reach preset temperature within 30
E23
minutes. Preheat cycle canceled.
E24
Microwave temperature reaches 500° F (260° C) in
overheat condition. Microwave cancels all functions.
E61
Sensor open error.
E62
Sensor shorted error.
E63
T1 Max Time error.
12
!
WARNING
Explanation
16027303
Possible Cause
Sticky keypad(s).
Motor and/or heater unplugged, wiring or PCB
assembly.
Sensor unplugged, wiring or PCB assembly.
Sensor unplugged, wiring or PCB assembly.
PCB assembly.
Sensor unplugged, wiring or PCB assembly.
Sensor unplugged, wiring or PCB assembly.
Convection heater or grill heater unplugged, wiring
or PCB assembly.
Thermal or gas sensor, wiring or PCB assembly.
Sensor unplugged, wiring or PCB assembly.
Sensor shorted or PCB assembly.
PCB assembly.
© 2006 Maytag Services