Sensor Error Code Display - Maytag JMV8186AA Series Service Manual

36" over-the-range domestic microwaves
Table of Contents

Advertisement

Troubleshooting Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to microwave and discharge
capacitors before servicing, unless testing requires power.

Sensor Error Code Display

Touchpad Display
E61
E62
NOTES: Replace blown fuse with 20 Amp fuse.
If the fuse is blown due to an improper switch operation, replace all interlock switches, PCB Assembly and
the fuse simultaneously, and ensure they are connected properly.
Check for microwave energy leakage after replacing interlock and monitor switches.
12
!
WARNING
Sensor open (unplugged, wiring or smart board)
Sensor shorted (unplugged, wiring or smart board)
Body latch
16026440
Error Mode
Door Sensing Switch
Interlock
Monitor
Switch
Primary Interlock Switch