Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to microwave oven and discharge the
high voltage capacitor before servicing, unless testing requires power.
Component
Touch Pad/Control
Removal of Touch
Panel
Pad/Control Panel is
required to perform test.
Check for continuity.
When touched: Less than
AMV5164BC*
400 Ω.
When not touched: More
than 1 mega Ω.
28
!
WARNING
Test Procedure
16027303
Results
Pad
1
2
3
4
5
6
7
8
9
0
Vegetables
Cook
Pizza Slice
Option
Baked Potato
Popcorn
Light Hi/Lo/Off
1 Pound Defrost
Add 30 Seconds
Reheat
Light Timer
Control Setup
Turntable On/Off
Kitchen Timer
Custom Program
Auto Defrost
Enter/Start
Clock
Power Level
Stop/Clear
Vent Hi/Lo/Off
Trace
Measurement
8 & 16
Continuity
7 & 16
Continuity
6 & 16
Continuity
5 & 16
Continuity
4 & 16
Continuity
3 & 16
Continuity
9 & 15
Continuity
8 & 15
Continuity
7 & 15
Continuity
9 & 16
Continuity
8 & 10
Continuity
9 & 10
Continuity
3 & 11
Continuity
2 & 12
Continuity
6 & 12
Continuity
7 & 12
Continuity
8 & 12
Continuity
9 & 12
Continuity
4 & 13
Continuity
5 & 13
Continuity
6 & 13
Continuity
7 & 13
Continuity
8 & 13
Continuity
9 & 13
Continuity
3 & 14
Continuity
4 & 14
Continuity
5 & 14
Continuity
9 & 14
Continuity
3 & 15
Continuity
4 & 15
Continuity
6 & 15
Continuity