Error Codes; Model Mmc5080Aa; Models Amc5143Aa* And Mmc5193Aa - Maytag UMC1071AAB/W Service Manual

Countertop domestic
Hide thumbs Also See for UMC1071AAB/W:
Table of Contents

Advertisement

Troubleshooting Procedures
Sensor Error Codes (Model MMC5080AA*)
Error Code
Error 1
Error 2
Error 3
Error 4
Sensor Error Codes (Models AMC5143AA* and MMC5193AA*)
Error Code
E1
E4
E5
12
Possible Cause
Shorted circuit.
Open circuit.
During cooling, sensor output was not less
then 4.7V within 3 minutes.
Door open when attempting to operate sensor
program.
Possible Cause
Exceeds 1 time limit setting.
Sensor open.
Sensor shorted.
• Allow oven to cool for 5 minutes.
• Check connection of wire at sensor.
• Check connection of wire at sensor.
• Allow oven to cool for 5 minutes.
• Close door, press PAUSE/CANCEL
and restart.
• Press the PAUSE/CANCEL key and
inspect the condition of the food.
• Check connection of wire at sensor.
• Allow oven to cool for 10 minutes.
16022923 Rev. 0
Correction
Correction
©2004 Maytag Services

Advertisement

Table of Contents
loading

Table of Contents