Maytag UMV1152CA Manual page 26

2006 over-the-range domestic microwaves
Hide thumbs Also See for UMV1152CA:
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to microwave oven and discharge the
high voltage capacitor before servicing, unless testing requires power.
Component
Touch Panel/Control
Panel
JMV8166BA*
26
!
Test Procedure
Removal of Touch
Pad/Control Panel is
required to perform
test.
Check for continuity.
When touched:
Less than 400 Ω.
When not touched:
More than 1 mega Ω.
WARNING
Pad
0
1
2
3
4
5
6
7
8
9
Control Setup
Pizza Slice
Baked Potato
Popcorn
Combination Cooking
Convection
Clock
Micro. Convection
Auto Cook
Auto Defrost
Reheat
Sensor Cook
Option
Snacks
Soften/Melt
Stop/Clear
Enter/Start
Power Level
Kitchen Timer
Delay Off
5 Speed
On/Off
Light Timer
Light Hi/Lo/Off
Turntable On/Off
Add 30 Seconds
16027303
Results
Trace
Measurement
5 & 13
Continuity
6 & 12
Continuity
5 & 12
Continuity
4 & 12
Continuity
3 & 12
Continuity
2 & 12
Continuity
9 & 13
Continuity
8 & 13
Continuity
7 & 13
Continuity
6 & 13
Continuity
2 & 10
Continuity
3 & 10
Continuity
4 & 10
Continuity
5 & 10
Continuity
6 & 10
Continuity
8 & 10
Continuity
2 & 11
Continuity
4 & 11
Continuity
6 & 11
Continuity
7 & 11
Continuity
8 & 11
Continuity
9 & 11
Continuity
1 & 11
Continuity
8 & 12
Continuity
9 & 12
Continuity
2 & 13
Continuity
3 & 13
Continuity
4 & 13
Continuity
2 & 14
Continuity
3 & 14
Continuity
4 & 14
Continuity
5 & 14
Continuity
6 & 14
Continuity
7 & 14
Continuity
8 & 14
Continuity
9 & 14
Continuity
© 2006 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents