Emg Code (Emergency Code); Msw Code - Sony DCR-PC10 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC10:
Table of Contents

Advertisement

4-2-4.

EMG Code (Emergency Code)

The emergency codes are stored in the addresses : 30, 34 and 38
corresponding to the types of errors occurred. Types of error code
are shown in the following table.
Code
00
No error (Initial state)
10
Loading motor time-out during LOAD
11
Loading motor time-out during UNLOAD
22
T reel error
23
S reel error
30
Capstan FG error
40
FG error during drum start-up
42
FG error during normal drum rotation
4-2-5.

MSW Code

MSW when errors occur:
Information on MSW (mode SW) when errors occur
MSW when movement starts:
Information on MSW when movements starts when the
mechanism position is moved (When the L motor is
moved)
MSW of target of movement:
Information on target MSW of movement when the
mechanism position is moved.
Mechanism Position
UNLOAD
EJECT BL
BL
USE
Releasing lock of
cassette compartment
Error Status
BL
BL
SOFF
DS
LS chassis movement range
BL STOP
BL
LE
FF
5-76
LOAD
BL
BL
RP
RVS
Pinch roller is pressed
Tension regulator ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc10e

Table of Contents