3-5-4.
BIST Check
4-1. Playback System Check
1) Set the POWER switch to VTR (or PLAYER) position.
2) Connect the adjustment remote commander and set the HOLD
switch to HOLD (SERVICE) position.
1. IC1701 (D1) playback system check
Mode
VTR playback
Signal
BIST signal
(Alignment tape XH5-6: NTSC)
(Alignment tape XH5-6P: PAL)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
4
Adjustment Address
14 to 19
Specified Value
NTSC model
E5 (Data of page: 4, address: 15)
11 (Data of page: 4, address: 14)
C0 to BA (Data of page: 4, address: 17)
6E to 04 (Data of page: 4, address: 16)
33 to B2 (Data of page: 4, address: 19)
59 to 19 (Data of page: 4, address: 18)
PAL model
27 (Data of page: 4, address: 15)
CA (Data of page: 4, address: 14)
DC (Data of page: 4, address: 17)
44 (Data of page: 4, address: 16)
A2 (Data of page: 4, address: 19)
03 (Data of page: 4, address: 18)
Check procedure:
Order
Page
Address
1
2
4
11
3
4
11
4
4
13
5
4
15
14
6
4
17
16
7
4
19
18
Data
Playback the alignment tape (XH5-6: NTSC, XH5-6P: PAL) in VTR mode.
04
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button.
03
After setting the data, press the PAUSE button. Data returns automatically to 00.
When the IC1701 (D1)
displayed in page: 4, address: 14 and 15.
When the IC1701 (D1)
be displayed in page: 4, address: 16 and 17.
When the IC1701 (D1)
displayed in page: 4, address: 18 and 19.
Procedure
IC1501 (U1) playback system is normal, following data will be
IC3500 (INDI) playback system is normal, following data will
IC1901 (A1) playback system is normal, following data will be
5-56