12
SERVICE WORK ON THE CHASSIS
12.48
Removing the engine guard (SIX DAYS)
–
Fill bleeding syringe
Bleed syringe (50329050000)
Hydraulic fluid (15) (
–
On the slave cylinder of the clutch, remove bleeder screw
ing syringe
B01224-10
–
Inject the liquid into the system until it escapes from hole
cylinder without bubbles.
–
To prevent overflow, drain fluid occasionally from the master cylinder reservoir.
–
Remove the bleeding syringe. Mount and tighten the bleeder screw.
–
Correct the fluid level of the hydraulic clutch.
Guideline
Fluid level under top edge of con-
tainer
400247-10
–
Position the cover with the membrane. Mount and tighten the screws.
(All 250/300 models)
–
Move the clutch fluid reservoir mounted on the handlebar to a horizontal posi-
tion.
–
Remove screws
–
Remove cover
B01538-10
–
Fill bleeding syringe
Bleed syringe (50329050000)
Brake fluid DOT 4 / DOT 5.1 (
–
On the slave cylinder of the clutch, remove bleeder screw
ing syringe
602757-10
–
Inject the liquid into the system until it escapes from hole
cylinder without bubbles.
–
To prevent overflow, drain fluid occasionally from the master cylinder reservoir.
–
Remove the bleeding syringe. Mount and tighten the bleeder screw.
–
Correct the fluid level of the hydraulic clutch.
Guideline
Fluid level under top edge of con-
tainer
B01540-10
–
Position the cover with the membrane. Mount and tighten the screws.
–
Turn quick release
guard.
B01204-10
with the appropriate hydraulic fluid.
4
p. 141)
.
4
.
1
with membrane
.
2
3
with the appropriate hydraulic fluid.
4
p. 140)
.
4
counterclockwise until it disengages. Remove the engine
1
and mount bleed-
5
of the master
6
4 mm (0.16 in)
and mount bleed-
5
of the master
6
4 mm (0.16 in)