Applysasconf Action; Choosing The Installation Disk - HP BL860c Administrator's Manual

Microsoft windows server 2008 sp2 and windows server 2008 r2 on integrity servers
Hide thumbs Also See for BL860c:
Table of Contents

Advertisement

2.
Boot to WinPE.
3.
Open a command prompt window.
4.
Run the hpshowdisk utility as follows:
run y:\utilities\hpshowdisk -n
5.
Find the disk you want in the list of disks and get the disk ID.
6.
Set the hbabootdevicediskid variable to the disk ID in the SSTKConfig.cmd script.
7.
Set the default_action variable to sethbabootdevice in the SSTKConfig.cmd script.
8.
Reboot to WinPE.
IMPORTANT:
Otherwise, the sethbabootdevice action will have no affect.
If the hbaapi.dll is not present in the utilities directory under the SSTK repository tree, this action
will not function correctly. In order to obtain that DLL, see the following issue in section 7 of the
readme file:
"HPshowdisk utility and SetHBABootDevice action do not work properly
if hbaapi.dll is not present"

applysasconf action

When the default_action variable is set to applysasconf, the ApplySASConf.cmd script
executes. If the target system is a BL860c, it applies RAID1 array configuration. If it is a BL870c,
it applies RAID1 + RAID1 array configuration.

Choosing the installation disk

By default, the toolkit installs Windows at the first disk (disk ID 0). If you want to install Windows
on another disk, the hpshowdisk tool can help you identify the target disk by showing disk details,
such as disk size and type.
To run hpshowdisk, follow these steps:
1.
Boot the target server using the commandprompt action.
2.
Open a Windows PE command prompt and enter hpshowdisk.
3.
Change to the y:\utilities directory.
4.
Run hpshowdisk -n.
Y:\utilities>hpshowdisk -n
HP Smart Array
HP Smart Array P400 Controller - 05132-B21
Disk ID 0: LUN 0 - 101.65 GB
HP PCIe Smart Array P411 SAS Controller - AM311A
Disk ID 1: LUN 0 - 169.43 GB
Disk ID 2: LUN 0 - 698.56 GB
If you want to install Windows on the disk connecting HP Smart Array P41 1, for example, choose
disk 1.
After you identify the installation disk, edit the following SSTK diskpart script to set the disk ID
of the installation disk:
diskpart\
default_layout_2008.txt
You must also edit the os\unattended_files\2008-server-version\unattended.xml
file (or unattended-JP.xml for Japanese Windows deployment) and set the disk ID of the
installation disk. For example:
<InstallTo>
<DiskID>1</DiskID>
</InstallTo>
Be sure there is at least one presentation configured to some Fibre Channel controller.
For installing Windows Server 2008 SP2 and Windows
Server 2008 R2
applysasconf action
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartsetup scripting toolkit

Table of Contents