HP BL860c Administrator's Manual page 40

Microsoft windows server 2008 sp2 and windows server 2008 r2 on integrity servers
Hide thumbs Also See for BL860c:
Table of Contents

Advertisement

Table 4 hpacuscripting Error Codes (continued)
Warning
Message
Code
2836
New Logical Drive ID does
not match the next available
Logical Drive ID
If you are attempting to
replicate a configuration
that has non-consecutive
logical drive numbers, then
you must change the script
file so that the logical
drive numbers are
consecutive.
2837
New Logical Drive ID already
exists
2838
Cannot create Logical Drive
2839
Cannot migrate Logical Drive
RAID
2841
Cannot extend Logical Drive
2842
Invalid RAID
2843
Invalid Size
2844
Invalid Stripe Size
2849
Invalid
ClearConfigurationWithDataLoss
parameter
2850
Controller does not support
Chassis Name
2851
Invalid Chassis Name
2852
Invalid SSP State
2853
Cannot change SSP settings
2854
Invalid SSP Adapter ID
2857
Invalid Surface Scan Delay
2861
Controller does not support
redundancy settings
2864
Invalid Preferred Path Mode
40
Utilities reference
Reason
The script file specifies a logical drive ID that is not the first unused
ID in the sequence. For example, if the controller has only Logical
Drive 1 and the script file attempts to create Logical Drive 3
(without Logical Drive 2), the script generates this error. This error
can occur when using an input file with logical drive numbers that
are not sequential. In this case, you must change the logical drive
numbers so that they are sequential in the input file.
When running in Configure mode, this error occurs when the
Logical Drive ID in the script file already exists in the configuration.
Configure mode can only create new logical drives.
The array has no free space, or the maximum number of logical
drives has already been reached.
The controller does not support RAID migration, or the current
controller configuration does not allow migration to occur.
The controller does not support extension, or the current controller
configuration cannot be extended. For example, extension is not
possible if the array has no free space.
The specified RAID is invalid or is not possible with the current
physical disk and aarray configuration.
The specified size is invalid or is not possible with the current
configuration.
The specified stripe size is invalid, not supported with the current
RAID level, or not supported with the current configuration.
The valid parameters are Yes and No (default).
The controller does not support setting a chassis name.
The entered chassis name is invalid. The chassis name can only
consist of the following characters: a-z, A-Z, 0-9, !, @, #, *, ( , )
, ,, - , _, +, :, ., /, and [space]. It cannot end with a space
character or exceed the maximum number of characters allowed
by the controller.
The requested SSP state is not a valid SSP state.
The SSP settings cannot be changed for the controller or logical
drive.
The adapter ID is not a valid adapter ID that was detected by the
controller.
The controller is not redundant or does not support redundancy
settings.
The preferred path mode specified is not a valid preferred path
mode, or the controller is not available.