Operating Instructions; Dc Voltage Measurements - Craftsman 82003 Owner's Manual

True rms multimeter
Hide thumbs Also See for 82003:
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

WARNING: Risk of electrocution. High-voltage circuits, both AC
and DC, are very dangerous and should be measured with great
care.
1. ALWAYS turn the function switch to the OFF position when the
meter is not in use.
2. If "OL" appears in the display during a measurement, the value
exceeds the range you have selected. Change to a higher range.
NOTE: On some low AC and DC voltage ranges, with the test
leads not connected to a device, the display may show a
random, changing reading. This is normal and is caused by
the high-input sensitivity. The reading will stabilize and give
a proper measurement when connected to a circuit.

DC VOLTAGE MEASUREMENTS

CAUTION: Do not measure DC voltages if a motor on the
circuit is being switched ON or OFF. Large voltage surges may
occur that can damage the meter.
1. Set the function switch to the V position.
2. Press the MODE button to select DC (if
necessary).
3. Insert the black test lead banana plug into
the negative COM jack.
Insert the red test lead banana plug into the
positive V jack.
4. Touch the black test probe tip to the negative
side of the circuit.
Touch the red test probe tip to the positive
side of the circuit.
5. Read the voltage in the display.