2-8 TELNET dedicated parameters
2
20
■ LOGIN check
Use this parameter to set whether or not to perform a login check when a client attempts to
connect to the robot controller.
When the login check is enabled, the user name and password are always checked when the client
attempts to connect to the robot controller. The client cannot connect the robot controller unless
the user name and password sent from the client match the data stored in the robot controller.
When the login check is disabled, the client can connect to the robot controller without a login
check and communication is possible right away.
Programming box display
8. login check
Input range
Default value
Valid
■ LOGIN user name
Use this parameter to set the login user name.
When the login check is enabled, the client must enter the user name specified here to connect to
the robot controller.
Programming box display
9. login user
1 to 8 characters
Input range
Default value
USER

■ LOGIN password

Use this parameter to set the login password.
When the login check is enabled, the client must enter the password specified here to connect to
the robot controller.
Programming box display
10. login password
1 to 8 characters
Input range
Default value
PASSWORD
■ LOGOUT processing
This parameter sets whether to stop the robot automatically or to continue the robot operation
when the client disconnects from the robot controller.
Programming box display
11. logout
Input range
Default value
Stop
* If TELNET connection is cut off due to an error, the robot operation stops automatically
regardless of the above setting.
F1
: Invalid
F2
: Valid
<Usable characters>
Alphabets
: A to Z
Numbers
: 0 to 9
Symbols
: ! " # $ % & ' ( ) + = . : ; – ? @ | { } _ ~
< > * , ^ [ ] /
<Usable characters>
Alphabets
: A to Z
Numbers
: 0 to 9
Symbols
: ! " # $ % & ' ( ) + = . : ; – ? @ | { } _ ~
< > * , ^ [ ] /
F1
: CONT. (Continues robot operation.)
F2
: Stop (Stops robot operation.)