QMS CrownCopy User Manual page 42

Table of Contents

Advertisement

Images are taking
too long to scan
The scanner lamp
flickers, is dim, or
fails to come on, or
the scanner
assembly stops in
the middle of the
scanner glass and
doesn't restart.
n
Check that you have at least 24 MB RAM
installed on the printer. This is the minimum
RAM required to operate CrownCopy; how-
ever, QMS recommends 40 MB to obtain the
fastest copying speeds.
n
Check that the Administration/Memory/
K Mem Emulation client has the required
amount of memory to operate CrownCopy.
Resolution
300
600
n
The scanner lamp is failing or has failed and
needs to be changed, or the bottom optional
assembly cover may be loose.
WARNING
QMS recommends that any hardware

maintenance on a non-functioning scanner be
performed by a QMS-authorized service
technician. QMS reserves the right to charge for
repairs necessitated by improper maintenance.
For QMS-authorized service, contact your QMS
vendor. If your QMS vendor doesn't provide
service, contact QMS to arrange service. See
appendix A, "QMS Customer Support," for
information on contacting us.
RAM (MB)
K Mem Emulation
24
852
24
2048
32
1024
40
10240
64
27648