HP ProLiant DL585 User Manual page 150

Proliant
Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

System LEDs and switches
Table E-10: QuickFind diagnostic display LEDs
Item
Description
8
Therm trip
9
SCSI interlock
10
Power supply 1
11
Power supply 2
12
Bus error
E-14
Status
Off = Normal
On = Attention required
Off = Normal
On = Attention required
Off = Normal
On = Attention required
Off = Normal
On = Attention required
Off = Normal
On = Attention required
continued
Action
The server experienced a thermal
shutdown.
If one of the CPU thermal LEDs is amber,
that CPU experienced an overtemperature
condition.
Be sure that the
processor heatsink is properly
attached. For more information, refer
to the maintenance and service guide.
Be sure the correct
DIMMs (1.2-inch) are installed.
Be sure all fans are
installed and working properly
Ensure the SCSI backplane is installed
properly.
Reseat SCSI backplane board and hard
drives.
Look at the LEDs on the front of the power
supply and take the appropriate action.
Look at the LEDs on the front of the power
supply and take the appropriate action.
A bus error occurred.
The error might have been caused by one
of the adapter cards on this bus (see amber
LEDs for which slots might have caused
the error).
Reseat the adapter cards.
If problem persists, remove or replace one
or both of the cards.
HP ProLiant DL585 Server User Guide