System LEDs and switches
Table E-5: Hot-plug SAS or SATA hard drive LED combinations
Online/Activity LED
(green)
On, off, or flashing
On, off, or flashing
On
On
Flashing regularly
(1 Hz)
Flashing regularly
(1 Hz)
Flashing irregularly
Flashing irregularly
E-6
Fault/UID LED
(amber/blue)
Alternating amber
and blue
Steadily blue
Amber, flashing
regularly (1 Hz)
Off
Amber, flashing
regularly (1 Hz)
Off
Amber, flashing
regularly (1 Hz)
Off
Interpretation
The drive has failed, or a predictive failure alert
has been received for this drive. It also has been
selected by a management application.
The drive is operating normally, and it has been
selected by a management application.
A predictive failure alert has been received for this
drive.
Replace the drive as soon as possible.
The drive is online, but it is not active currently.
Do not remove the drive. Removing a drive
may terminate the current operation and cause
data loss.
The drive is part of an array that is undergoing
capacity expansion or stripe migration, but a
predictive failure alert has been received for this
drive. To minimize the risk of data loss, do not
replace the drive until the expansion or migration
is complete.
Do not remove the drive. Removing a drive
may terminate the current operation and cause
data loss.
The drive is rebuilding, or it is part of an array that
is undergoing capacity expansion or stripe
migration.
The drive is active, but a predictive failure alert
has been received for this drive. Replace the drive
as soon as possible.
The drive is active, and it is operating normally.
HP ProLiant DL585 Server User Guide