HP ProLiant DL585 User Manual page 149

Proliant
Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

Table E-10: QuickFind diagnostic display LEDs
Item
Description
3
Processor
memory board
4
Processor
power module
5
Temperature
6
DIMM
7
I/O power fault
HP ProLiant DL585 Server User Guide
Status
Off = Normal
On = Attention required
Off = Normal
On = Attention required
Off = Normal
On = Attention required
Off = Normal
On = Attention required
Off = Normal
On = Attention required
System LEDs and switches
continued
Action
Processor memory board power failure. If
problem persists, replace the processor or
processor memory board.
PPM power failure. If problem persists,
replace PPM.
If the PPM and the BRD LEDs are both on,
there is a configuration error.
One or more components have
experienced an elevated temperature or a
thermal shutdown.
A thermal shutdown is indicated by the
Therm Trip LED.
Be sure the processor
heatsink is properly attached.
Be sure there are no 1.7"
DIMMs installed that prevent airflow
across the processor heatsink).
Be sure that all fans are
installed and working properly.
Be sure that the server
environment meets posted
requirements.
For information about server environment
requirements refer to the "Optimum
environment" section in Chapter 3.
DIMM failure or configuration error. Refer to
the IML or POST messages
A power fault on the system I/O board
occurred. If problem persists, replace the
system I/O board.
continued
E-13

Advertisement

Table of Contents
loading

Table of Contents