17.7.8 Log Sense Page E
This page contains the start-stop cycle information.
Table 57: Log Sense Page E
Byte
7
0
Reserved
1
2-3
4-5
6
DU=0
7
8-11
12-13
14-15
16
DU=0
17
18-21
22-23
24-25
26
DU=0
27
28-31
32-33
34
DU=0
35
36-39
The week and year that the device was manufactured shall be set in the parameter field defined by parameter code 0001h. The
date of manufacture cannot be saved using the LOG SELECT command. The data is expected in numeric ASCII characters
(30-39h) in the form YYYYWW. The accounting date specified by parameter code 0002h is a parameter that can be saved
using the LOG SELECT command.
6
5
4
Reserved
PageLength = 24h
Parameter Code = 0001h
DS=1
TSD=0
ETC=0
Parameter Length = 06h
Year of Manufacture (4 ASCII characters)
Week of Manufacture (2 ASCII characters)
Parameter Code 0002h
DS=0
TSD=0
ETC=0
Parameter Length = 06h
Accounting Date Year (4 ASCII characters)
Accounting Date Week (2 ASCII characters)
Parameter Code 0003h
DS=1
TSD=0
ETC=0
Parameter Length = 04h
Specified cycle count over device lifetime
Parameter Code 0004h
DS=1
TSD=0
ETC=0
Parameter Length = 04h
Accumulated start-stop cycles (4 byte binary number)
Hitachi Ultrastar 15K147 SCSI Hard Disk Drive Specification
Bit
3
2
Page code = 0Eh
TMC = 0
LBIN=0
TMC = 0
LBIN=0
TMC = 0
LBIN=1
TMC = 0
LBIN=1
92
1
0
LP = 1
LP=1
LP=1
LP=1