Bosch B450 Installation & Operation Manual page 31

Conettix plug-in communicator interface
Table of Contents

Advertisement

Conettix Plug-in Communicator
Interface
Option
Press
to
Select
1. Modify
1
Diagnostic
Settings
2. Re-print All
2
Console Message
3. Enable Live
3
Console
Messages
Table 5.4: Diagnostic Log sub-menu parameters
SMS and USB configuration parameters
Notice!
The table below shows all parameters available through SMS or USB configuration. Values in
bold are default settings.
ID
Parameter
1
Current Password
2
New Password
13
TCP/UDP Port
Number
15
AES Encryption
16
AES Encryption Key 32, 48, or 64 digits max.
19
Tamper (for GV4
v1.0.x control
panels)
Bosch Security Systems, Inc.
Description
The Diagnostic logging is intended for use only under Bosch direction. Diagnostic
settings determine which types of messages to display.
The Re-print all option prints any diagnostic messages that have already occurred and
are stored in the B450's buffer. This can print what just happened if an issue occurs.
Enable live console messages provides real time output of diagnostic messages. This
allows the PC running TeraTerm to log what is occurring in the module and can log
for longer periods of time.
Values
4 to 10 characters (B450)
4 to 10 characters
1 to 65535 (7700)
0 = Disabled
1 = 128 bit, 2 = 192 bit, 3 = 256
bit
0-9, A-F, a-f allowed
01020304050607080910111213
14151617181920212223242526
272829303132
0 = Disabled
1 = Enabled
Installation and Operation Guide
Description
Mandatory and case sensitive.
Notice!
Make sure you record and record your password.
New password, as desired. Case sensitive.
Sets the source port for the B450.
Security encryption on or off. The setting must
match the encryption settings in the receiver.
Notice!
This setting applies to SDI, and GV4 v1.0.x control
panels only.
The AES Encryption Key must match the encryption
key in the receiver.
Notice!
This setting applies to SDI, and GV4 v1.0.x control
panels only.
When enabled, allows tamper and tamper restore
conditions to be reported to an SDI2 control panel.
Notice!
Only control panels with a SDI2 bus connection to
the B450 can report a tamper condition.
Configuration | en