Bosch B450 Installation & Operation Manual page 29

Conettix plug-in communicator interface
Table of Contents

Advertisement

Conettix Plug-in Communicator
Interface
Option
Press
to
Select
1. Status (Starts
1
with Basic
Status)
2. Change
2
Passcode
3. Basic
3
Configuration
4. Advanced
4
Configuration
5. Reset to
5
Factory Defaults
6. Diagnostic Log 6
7. Firmware
7
Update
8. Save and Exit
8
9. Exit
9
Table 5.2: USB Main Menu parameters
Status sub-menu parameters
For a description of the Status sub-menu parameters (Reset Status, Signal Strength, and
Product Versions), refer to the table below.
To go to a specific menu option, enter the appropriate menu item number to enter that item.
Bosch Security Systems, Inc.
Description
To access and view the link, modem, and bus status
For additional menu descriptions, refer to the USB Status sub-menu parameters table
below for more information.
To change the login passcode, enter the new passcode twice. The second entry
confirms the new passcode.
Passcodes must be 4-10 characters long, and are case-sensitive.
0-9, A-Z, a-z, and special characters are allowed.
Notice!
If SMS configuration is used, do not use semicolon (;) or exclaimation mark (!) as
part of the passcode.
Select to program Basic Configuration options. Press 0 to return to the Main menu.
To change a basic parameter, select the option to change, and then enter in the new
value.
Select to program Advanced Configuration options. Press 0 to return to the Main
menu.
To change an advanced parameter, select the option to change, and then enter in the
new value.
Select to reset all factory default values. All fields are cleared and the factory default
values are restored.
Notice!
A non-defaulted SDI2 control panel will overwrite the default settings if connected to
the defaulted module.
Select to review the Diagnostic log.
Select this option to update the firmware in the B450.
Notice!
Download your update file from the Bosch website prior to performing an update.
For more information on Firmware update workflows, refer to Firmware Update page,
page 35.
Press 8 to save changes and exit the menu.
A message of Changes saved displays in the window. This occurs if changes have
been made, otherwise a message of No changes made displays in the window.
Select to exit the menu and log out. You must enter the passcode to log back in.
Notice!
If configuration changes have been made, and the Exit option is selected, those
changes are discarded.
Installation and Operation Guide
Configuration | en
29
2013.09 | 02 | F.01U.282.875