Configuration

Notice!
Power up the system prior to the configuration workflows described in this chapter.
You can configure the B450 using one of the methods described in this section for your
control panel type.
5.1

Plug and Play configuration

When installing under the following conditions, the B450 needs no further configuration:
5.2

Configuration for SDI2 control panels

Notice!
By default, when connecting a field replacement B450 to an existing SDI2 control panel, the
control panel overrides some of the module settings such as; TCP/UDP Port Number, AES
Encryption, Tamper, Panel Programming, IPv4 DNS Server IP Address, Alternate IPv4 DNS
Server IP Address, and TCP Keep Alive Time. To keep custom module settings when you
connect a module to a configured control panel, you must disable Panel Programming prior to
connecting to the SDI2 bus. This is accomplished by using either USB, or SMS configuration.
If the SDI2 control panel is not defaulted, the panel sends the network configuration
parameters to the B450.
Address-only configuration conditions
An SDI2 control panel automatically configures a newly connected module.
1.
2.
3.
The control panel stores the module settings and automatically programs a defaulted module
when connected. If manual module programming is required, use USB or SMS configuration to
set the Panel Programming parameter to Disabled before installing.
5.2.1

Configuring and viewing status from RPS

For SDI2 control panels, the networking related parameters in the Networking parameters in
RPS table can be configured through the panel or RPS. When cellular specific parameters need
to be modified, refer to the USB or SMS configuration sections within this installation and
operation guide for programming workflows and operation.
The B450 parameters within RPS can be found under the SDI2 Modules section under B42x
Ethernet Communicator. The B426 and the B450 modules share these parameters. Refer to
the illustration below for RPS menu selections.
Bosch Security Systems, Inc.
AES encryption is not required.
Low signal delay can be no more than 200 sec.
If the control panel is not at factory default, it transfers the configuration settings in the
control panel to the B450.
Set the address switch to the correct address for the control panel (SDI2 control panels
use address 1 or 2).
Program the control panel communication settings using RPS or the keypad.