Configuration; Configuration Parameters - Bosch B450-M Installation Manual

Table of Contents

Advertisement

Conettix Plug-in Communicator
5

Configuration

Configure the module using one of the methods described in this section. Not all options work
for all control panel types.
5.1

Configuration parameters

Use this information to program a control panel for PnP, for USB configuration, or for SMS
configuration. In this section, the parameters are listed in the order you see them in the USB
menus. Not all parameters are available in all configuration programs.
(USB menu [3] Basic Configuration)
TCP/UDP Port Number
Default: 7700
Selections: 0 - 65535
For IP communications with RPS, automation, or Remote Security Control (RSC) in typical
installations, keep the TCP/UDP Port at the default
AES Encryption
Default:  No Encryption
Selections:
Select the AES key size.
Module Enclosure Tamper
Default: No - Disable
Selections:
When the tamper input is enabled and connected to a Bosch ICP-EZTS tamper switch, the
control panel creates a tamper event when the enclosure door is opened, or when the
enclosure is removed from the wall.
Panel Programming Enable
Default: Yes
Selections: Yes, No
Yes - Control panel programming is enabled.
No - Control panel programming is disabled.
Notice!
Do not disable
Do not disable panel programming unless you use an SDI2 control panel or AMAX 2100/
3000/ 4000 with Panel Programming Enable enabled. Do not disable Web Access Enable and
Panel Programming Enable.
Bosch Security Systems, Inc.
Plug and Play (PnP) configuration, page 21 (SDI2 and some option bus control panels)
USB configuration, page 22 (all control panels)
SMS configuration, page 34 (all control panels)
No Encryption
128 bits - 16 bytes
192-bit - 24 bytes
256-bit - 32 bytes
Yes - enable enclosure tamper input
No - disable enclosure tamper input
Installation Manual
Configuration | en
17