Programming Overview For The D6600 - Bosch Conettix ITS-D6682-INTL Installation Manual

Table of Contents

Advertisement

Conettix ITS-D6682-INTL | Installation Guide | 3.0 Configuring and Programming the D6682
27. If you want to enable encryption, select 6
Security from the main menu and continue
with Step 28.
If encryption is enabled on the D6682
(refer to Figure 11), you must enable it
on all field devices (C900TTL-E,
D9133TTL-E, DX4020) with the same
key. Encryption must also be enabled in
the D6600 Receiver. Refer to the D6600
Program Entry Guide (P/N:
4998122702).
The network interface module (D6682,
C900TTL-E, D9133TTL-E, or DX4020)
must have the proper software version
to support encryption. For more details,
refer to the Device Installer Operation
and Installation Guide (P/N:
4998138688).
Figure 11: D6682 Encryption
28. At Disable SNMP (N) N, press [ENTER].
29. At SNMP Community Name ( ):
press [ENTER].
30. At Disable Telnet Setup (N) N,
press [ENTER].
31. At Disable Port 77Feh (N) N, press
[ENTER].
32. At Disable Web Server (N) N,
press [ENTER].
33. At Disable ECHO ports (Y) Y,
press [ENTER].
34. At Enable Encryption (N), press [ENTER].
35. At Change keys (N), press [Y]. Enter keys as
follows:
These 16 bytes (32 characters) should
-
match the bytes programmed in the
D6682.
Default value is 01-02-03-04-05-06-07-
-
08-09-10-11-12-13-14-15-16.
36. At Enable Enhanced Password (N),
press [ENTER].
10
After you make all the changes and
verify them for accuracy, you must save
the information.
37. Select 9 – save and exit. When the
connection to host is lost, press [ENTER] to
continue.
3.7
Programming Overview for the
D6600
The D6600 Receiver is shipped with factory default
program parameters and features already installed.
Descriptions of the program items are found in the
D6600 Program Entry Guide (P/N: 4998122702).
Many of the operational features of the D6600 can be
altered through programming options. The
programming options you choose depend on:
The type(s) of peripheral reporting device(s) used
in your central station (for example external
printer or automation computer)
The supervision characteristics for these devices
The type of communicators reporting to the
receiver
The number and type of receiving lines in use
Sending the files back to the D6600
(CPU/Host/Network, Account Database, or Line
Card)
Upgrading the Software installed in the D6600
(CPU, System, or PSTN line cards)
Refer to the D6200 Software Operation and
Installation Guide (P/N: 4998154991) for information
and procedures on how to accomplish these tasks.