Using Telnet With Windows Nt, Windows 2000, Or Windows Xp; Programming Overview For The D6600; Figure 14: Command Prompt - Telnet; Figure 15: Port Value Change - Bosch Conettix D6680 Installation Instructions Manual

Ethernet network adapter
Table of Contents

Advertisement

Conettix D6680 | Installation Instructions | 3.0 Configuration and Programming
32. At Enable Enhanced Password (N), press
[ENTER].
After you make all the changes and verify
them for accuracy, you must save the
information.
33. Select 9 – save and exit. When the connection to
host is lost, press [ENTER] to continue.
3.5.2 Using Telnet with Windows NT, Windows
2000, or Windows XP
Although the screen captures are specific
to Windows 2000, they are similar for
Windows NT and XP.
To complete the IP address configuration of the
D6680, launch a telnet session:
You must be logged into Windows with an
administrator privilege level.
This example uses the IP address of
10.25.124.148 and the MAC Address of
00-20-4a-51-01-a7
1. Select Start � Run to open an MS-DOS window.
2. Type telnet and click OK.
A DOS window appears:
12
Available from A1 Security Cameras
www.a1securitycameras.com email: sales@a1securitycameras.com
The colors are inverted here for clarity. The
normal prompt window appears with white
text on black.
3. At the C:\> prompt, type telnet and press
[ENTER].
4. At the Microsoft Telnet> prompt, type open
(space) IP Address (space) Port Number.

Figure 14: Command Prompt - telnet

Example:
open 190.220.128.219 1
5. The connection fails the first time. This is normal.
Press [F3] to show the last line typed.
Backspace over the port value and change it to
9999.

Figure 15: Port Value Change

Example:
open 190.220.128.219 9999
6. Press [ENTER].
7. Do Steps 8 through 32 in Section 3.5.1 Using Telnet
with Windows 98SE or ME on page 8.
Configuration of the D6680 is complete. Perform this
procedure again for any additional D6680s.
3.6
Programming Overview for the
D6600
The D6600 Receiver is shipped with factory default
program parameters and features already installed.
Descriptions of the program items are found in the
D6600 Program Entry Guide (P/N: 4998122702). Many
of the operational features of the D6600 can be altered
through programming options. The programming
options you choose depend on:
Bosch Security Systems, Inc. | 5/07 | 4998138732-01

Advertisement

Table of Contents
loading

Table of Contents