en | Connection
5
Connection
Notice!
The PoE ports "Data In" and "Data & Power Out" are shielded
RJ45 data sockets. They cannot be used as "Plain Old Tele-
phone Service" (POTS) telephone sockets. Connect only RJ45
i
data connectors (EIA 568A and 568B) to these ports.
The "Data In" and "Data & Power Out" interfaces are qualified
as "Safety Extra Low Voltage" (SELV) circuits according to IEC
60950-1. These interfaces can be connected only to SELV inter-
faces on other equipment.
1.
2.
3.
2013.03 | 1.2 | F.01U.279.929
Connect the midspan to an AC power outlet (100 – 240
VAC), using one of the two power cords supplied, or one
that has the appropriate ratings and specifications (see the
Safety chapter).
Note: The voltage of the power outlet must match the
voltage indicated on the midspan label.
Connect the Data In (input) port to the remote Ethernet
network switch.
Connect the Data & Power Out (output) port to the
Ethernet port on the AutoDome camera.
Note: Do NOT use cross-over cable!