Alarm Activated Pre-Position; Sample Alarm Responses - Bosch LTC 8600 Instruction Manual

Allegiant microprocessorbased video switcher/control systems cpu firmware version 10.0
Table of Contents

Advertisement

LTC 8600 | LTC 8800 Series

16.5 Alarm Activated Pre-position

16.6 Sample Alarm Responses

F.01U.127.393 | 2.0 | 2009.03
Alarm activated pre-position capability exists in each of the three (3) alarm
response modes. This enables a pan/tilt/zoom equipped camera to automatically
position itself to a preprogrammed scene as a result of an alarm signal. When using
conventional pan/tilt equipped devices and zoom lenses, they must have the neces-
sary options for pre-position control. The system default is to activate pre-position
#16 of the system camera receiving an alarm. Using the optional LTC 8059/00 MCS
package or the optional LTC 8850/00 GUI Software package, the user can configure
a response to alarms as required.
Basic Mode
In the Basic alarm response mode, cam-
eras are individually armed for each
alarm monitor.
Alarm Status
Alarm Station Display
st
1
Alarm
Video associated with 1
alarm is displayed on any or
all appropriately armed
monitors.
nd
2
Alarm
Video associated with 2
alarm is displayed on any or
all appropriately armed
monitors.
rd
3
Alarm
Video associated with 3
alarm is displayed on any or
all appropriately armed
monitors.
Monitors and their respectively armed
cameras are programmed individually.
Multiple alarms on monitors are
sequenced automatically.
Alarmed video remains on monitors for
duration of alarm input signal.
Auto-Build Mode
In the Auto-Build alarm response mode,
alarms "build-up" on armed monitors as
new alarms are received.
Alarm Status
st
st
1
Alarm
nd
nd
2
Alarm
rd
rd
3
Alarm
.
.
.
th
8
Alarm
th
9
Alarm
Any number of monitors may be armed.
Multiple alarms on monitors are
sequenced automatically. Alarm video
remains on monitors for duration of
alarm input signal.
Instruction Manual
en | 59
Alarm Station Display
Video associated with
st
1
alarm is displayed
on monitor # 1 (if
armed).
Video associated with
nd
2
alarm is displayed
on monitor # 2 (if
armed).
Video associated with
rd
3
alarm is displayed
on monitor # 3 (if
armed).
Video associated with
th
8
alarm is displayed
on monitor # 8 (if
armed).
Video associated with
th
9
alarm is sequenced
with video of 1st alarm
on monitor # 1.
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents